Differences
This shows you the differences between two versions of the page.
Both sides previous revision Previous revision | Last revision Both sides next revision | ||
infrastructure:services:accesscontrol [2020/01/18 13:45] |
infrastructure:services:accesscontrol [2020/04/11 12:01] 127.0.0.1 external edit |
||
---|---|---|---|
Line 1: | Line 1: | ||
+ | |||
===== Our Current System ===== | ===== Our Current System ===== | ||
Our current system uses ESP8266 based hardware for WiFi-enabled doors, interlocks and vending machine controls. | Our current system uses ESP8266 based hardware for WiFi-enabled doors, interlocks and vending machine controls. | ||
Line 11: | Line 12: | ||
=== Interlocks === | === Interlocks === | ||
+ | {{:infrastructure:interlockoutside.jpg?400|}} | ||
+ | |||
Interlocks contains a Sonoff TH10, a 240v 20A 2Pole NO contactor, a 3.3v RFID reader and a single 20mm threaded case WS2812b led on a custom PCB that is wired into a TRRS connector on the sonoff. | Interlocks contains a Sonoff TH10, a 240v 20A 2Pole NO contactor, a 3.3v RFID reader and a single 20mm threaded case WS2812b led on a custom PCB that is wired into a TRRS connector on the sonoff. | ||
+ | |||
+ | PCB Project: https://easyeda.com/wodann/Interlock_Buzzer-10cdd361c1e342e8851967c3ef5db927 | ||
Wiring Diagram: | Wiring Diagram: | ||
{{ :infrastructure:interlock_v2_wiring_diagram.pdf |}} | {{ :infrastructure:interlock_v2_wiring_diagram.pdf |}} | ||
- | === Vending Machines === | + | === Drinks Vending Machines === |
The vending machines run a USB powered ESP8266 board (Wemos D1 Mini) that triggers a drink dispense via a relay. | The vending machines run a USB powered ESP8266 board (Wemos D1 Mini) that triggers a drink dispense via a relay. | ||
+ | |||
+ | PCB Project: https://easyeda.com/wodann/Spacebucks-Drinks-D1 | ||
+ | |||
+ | === Magnetic Door Holders === | ||
+ | {{:infrastructure:maglocks.jpg?400|}} | ||
+ | |||
+ | Our magnetic door holders use a Sonoff SV with a commercial 24v magnetic door holder and a reed switch. The firmware turns on the relay output for 150 seconds after the reed switch closes. | ||
=== Useful Info === | === Useful Info === |
- infrastructure/services/accesscontrol
- Last modified: 3 years ago
- by jabelone